Xác Định Sắt Trong Nước
Embed This Widget
Add the script tag and a data attribute to embed this widget.
Embed via iframe for maximum compatibility.
<iframe src="https://chemfyi.com/iframe/entity//" width="420" height="400" frameborder="0" style="border:0;border-radius:10px;max-width:100%" loading="lazy"></iframe>
Paste this URL in WordPress, Medium, or any oEmbed-compatible platform.
https://chemfyi.com/entity//
Add a dynamic SVG badge to your README or docs.
[](https://chemfyi.com/entity//)
Use the native HTML custom element.
Đo nồng độ sắt hòa tan bằng phép đo màu thioxianat
Mục tiêu
Xác định nồng độ sắt(III) trong mẫu nước bằng phương pháp đo màu thioxianat.
Bối cảnh
Iron(III) ions react with thiocyanate ions (SCN⁻) to form the intensely red-colored complex [Fe(SCN)]²⁺. The intensity of the red color is proportional to the Fe³⁺ concentration, following the Beer-Lambert law. This method is widely used in water quality testing and environmental monitoring. Students learn both the analytical technique and the chemistry of complex ion formation.
Cảnh báo an toàn
- FeCl₃ solution stains skin and clothing
- KSCN is harmful if swallowed
- HNO₃ is corrosive — handle with care
- Dispose of thiocyanate waste in designated containers
PPE cần thiết
Vật liệu
-
Iron(III) chloride (FeCl₃) standard (100 mL)0.01 M stock solution
-
Potassium thiocyanate (KSCN) (100 mL)0.1 M solution
-
Dilute HNO₃ (0.1 M) (50 mL)To maintain acidity
-
Water sample (50 mL)Unknown iron content
-
Distilled water (500 mL)For dilutions
Thiết bị
Quy trình
Prepare a series of standard Fe³⁺ solutions (0, 1, 2, 4, 6, 8, 10 ppm) by diluting the stock FeCl₃ solution in 50 mL volumetric flasks.
Add 5 mL of 0.1 M KSCN and 2 mL of dilute HNO₃ to each standard flask and the water sample. Make up to volume with distilled water.
Allow 5 minutes for full color development. The solutions should range from pale to deep red.
Set the colorimeter to 480 nm. Zero with the blank solution (0 ppm Fe³⁺ + KSCN).
Measure the absorbance of each standard solution and the water sample.
Plot the calibration curve (absorbance vs. concentration). Use it to determine the iron concentration in the water sample.
Calculate the iron concentration and evaluate whether the water meets drinking water standards (<0.3 ppm).
Kết quả dự kiến
The calibration curve should be linear from 0 to 10 ppm. The deep red color of [Fe(SCN)]²⁺ intensifies with increasing Fe³⁺ concentration. The water sample's iron content is determined from the calibration curve.
Dọn dẹp
Collect all thiocyanate-containing solutions in labeled waste. Rinse all glassware thoroughly. Wipe down the colorimeter.
Chi tiết
- Danh mục
- Colorimetry
- Độ khó
- Intermediate (High School)
- Thời gian
- 75 phút
- Chi phí ước tính
- $10,00
- Số bước
- 7
- Vật liệu
- 5